Community energy · 06
Commercial launch of a community: seven conditions before sharing becomes billing
The law already allows a community to be set up, but from a charter to the first bill that reflects shared energy there are seven steps. A community can take some of them now; others depend on NEURC decisions and DataHub readiness. Below is what each step requires, which rule it rests on and what can already be done.
Seven launch conditions
- 01Community legal entity
- 02Member agreements
- 03Verified metering points / EIC
- 04Official metering and virtual point
- 05Allocation algorithm
- 06Supplier, BRP, invoices
- 07Pilot reconciliation
1. The community legal entity
A community energy organisation is a legal entity voluntarily formed by individuals, small and micro enterprises and/or local authorities, whose main purpose is not profit (Art. 1 of Law 2019-VIII). Under Art. 58-2 it may be set up as a public association, as a condominium association (OSBB) or in another non-profit form permitted by law.
| Form | Suits | Watch out for |
|---|---|---|
| Condominium association (OSBB) | An apartment building with rooftop PV | General meeting decision; whether all co-owners become members; the building’s common loads |
| Public association | Residents of several buildings, villages, mixed communities | The charter must expressly cover energy activity, membership, exit and the algorithm |
| Another non-profit form (e.g. cooperative, association) | A community with a municipality and businesses | Check that the form admits these members and has no profit-distribution purpose |
The charter sets out: members and their rights, joining and leaving, approval and change of the allocation algorithm (draft p. 10.3.10), how the internal price is set and how surplus revenue is used.
2. Contracts
| Contract | Parties | Covers | Basis |
|---|---|---|---|
| Participation | The community and each member | Algorithm, price of shared energy, settlement, data consent, exit | Civil law; draft p. 10.3.15 |
| Supply (residual) | Member and supplier | Energy beyond the community share. The member keeps the right to switch | Retail rules; Art. 58-2 parts 2, 9 |
| Sale of surplus | Community and buyer (trader, supplier, market) | Energy not allocated to members | Art. 58-2: participation in all market segments |
| Imbalance settlement | Community and a BRP (unless the community becomes one) | Financial responsibility for deviations | Draft p. 10.3.18 |
| Metering | Community and metering service provider | Metering of generation, algorithm parameters | Draft pp. 10.3.9, 10.3.11 |
| Administration (optional) | Community and administrator | Register, data, calculations, reports on its behalf, without a licensed status | Proposal GEO-SUP-01 (not adopted) |
3. Verified metering points and EIC codes
Each member brings one or more metering points, each with an EIC code in DataHub. The community keeps a register of members with their EIC codes (draft p. 10.3.9). One wrong code means shared energy is credited to the wrong customer or counted twice.
- The member confirms the metering point is theirs and consents to its inclusion.
- The register records when each point joined and left, so settlement for past periods stays reproducible (proposal GEO-03).
- A point’s EIC code does not replace the member’s identity: one person may have several points, and a point may change owner (GEO-SUP-02).
4. Official metering and the virtual metering point
Settlement can only use certified metering data: interval (15- or 60-minute) smart-meter data read and validated by the metering service provider and certified by the metering administrator in DataHub (draft pp. 10.3.13, 10.3.14). Data from one’s own sensors, inverters or apps is fine for modelling, not for bills.
The draft provides for a virtual community metering point in DataHub aggregating all members’ points (p. 10.3.7). How it is created, changed and tested is not yet defined. Wesfin Flex proposed setting this out in the Metering Code and the administrator’s rules, and meanwhile not treating unverified data as certified (GEO-02).
5. The allocation algorithm
The community’s charter approves the algorithm, and its parameters go to the metering service provider (draft pp. 10.3.9, 10.3.10). The draft offers static (fixed percentages) and dynamic (in proportion to consumption in the interval) algorithms. See How energy sharing works.
- Each version has a number and an effective date; a change does not rewrite past periods.
- A member’s share in an interval cannot exceed their actual consumption, and the sum of shares cannot exceed available generation (GEO-SUP-03).
- Members get an explanation of how their share was calculated and can ask for reconciliation (GEO-05).
6. Financial settlement and market participants
After allocation a member has two volumes: energy from the community and residual energy from the supplier. Under the draft the supplier bills the residual on the basis of certified data (p. 10.3.13), and each member pays network services at the Regulator’s tariffs (p. 10.3.16). The member pays the community for its share at the internal price in the participation agreement.
| Payment | Payer | Payee | Basis |
|---|---|---|---|
| Shared energy | Member | Community | Participation agreement; share per algorithm |
| Residual energy | Member | Supplier | Certified data accounting for allocation |
| Distribution and transmission | Member (via supplier or directly) | DSO, TSO | NEURC tariffs; volumes accounting for internal allocation |
| Surplus | Buyer | Community | Sale contract |
| Imbalances | Community or its BRP | TSO / BRP | Market rules; draft p. 10.3.18 |
A community may participate in the market itself or through an aggregator (draft p. 10.3.3). Wesfin Flex proposed clarifying that the community chooses its aggregator and that market participation does not automatically confer BRP status or a licence (GEO-01). Leaving the community and switching supplier follow the general procedure (p. 10.3.20).
7. Pilot reconciliation
Before the first real bill, run a few months “in shadow”: calculate shares alongside current bills, reconcile the community’s, the metering provider’s and the supplier’s results and show members how their bill would have changed. This catches errors in EICs, time intervals and the algorithm before they become money.
What a community can do now
| Condition | Possible now | Waiting for |
|---|---|---|
| Legal entity | Yes | – |
| Contracts | Prepare drafts | Final retail rules |
| Metering points and EICs | Collect and check codes, member consents | Confirmation procedure in the Metering Code |
| Official metering | Check meters and metering provider | Virtual point and data exchange procedure |
| Algorithm | Choose and model | Adoption of p. 10.3.10 |
| Settlement, BRP | Talk to supplier and BRP | Adoption of the resolution; tax guidance |
| Pilot reconciliation | Modelling on test data | Access to certified data |
Wesfin GEO helps with preparation: member and consent register, metering point checks, modelling of algorithms on test data. The platform does not run commercial settlement until the conditions above are met. See Wesfin GEO, Flex and EDDIE.
Sources
- Law No. 2019-VIII, Arts. 1, 58-2 (in Ukrainian) (opens in a new tab) · Verkhovna Rada of Ukraine
In force: definition, forms, member rights.
- NEURC draft resolution of 4 Nov 2026 (in Ukrainian) (opens in a new tab) · NEURC
A draft, not adopted. Chapter 10.3 points as quoted in submissions Nos. 59 and 66.
- Retail Electricity Market Rules (NEURC resolution No. 312, in Ukrainian) (opens in a new tab) · NEURC
- Commercial Metering Code (NEURC resolution No. 311, in Ukrainian) (opens in a new tab) · NEURC
- Wesfin Flex submission No. 59 of 10 Nov 2026 (PDF, Ukrainian) · Wesfin Flex LLC
GEO-01 to GEO-09. Proposals, not adopted.
- Wesfin Flex submission No. 66 of 17 Nov 2026 (PDF, Ukrainian) · Wesfin Flex LLC
GEO-SUP-01 to 08, GEO-TAR-01, 02. Proposals, not adopted.
This is an explanatory text by Wesfin, not legal advice. Legal acts are quoted from official texts as of the check date; verify the current version before acting.
Read next
- Learn
How energy sharing works in a community: metering, algorithms, roles
Physical flows versus accounting allocation, static and dynamic algorithms on 15-minute data, surplus, storage, a member’s bill and the roles of market parties.
- Regulation
Open questions: what is still unresolved for launching communities
Thirteen questions neither the law nor the NEURC draft answers: the virtual metering point, data access, proximity tariffs, the administrator, imbalances, taxation. Who should settle them and what Wesfin proposes.
- Regulation
NEURC draft resolution of 4 Nov 2026: the community energy-sharing procedure
What the draft amendments to retail rules No. 312 and procedure No. 2651 propose: chapter 10.3 on communities, a virtual metering point in DataHub, static and dynamic algorithms, imbalances, member exit, a 10 kWh threshold. A draft, not adopted.